Anisotropic Conductive Film (ACF) for Chip On Glass for small-to-medium-sized LCDs
Suitable for direct mounting of driver IC which drives a flat panel display onto glass substrate.
With both excellent conductivity and insulating property between terminals for fine pitch connection.
- CP6920F/CP6920F3
- CP30941-20AB

| CP30941-20AB | |
| For small-to-medium-sized LCDs | |
|
|
|

| Product Name | CP30941-20AB | |
|---|---|---|
| Type | COG | |
| Connection material | IC | |
| ITO Glass | ||
| Minimum space (µm) *1 | 13 | |
| Minimum pitch (µm) *2 | - | |
| Minimum connection area (µm2) *3 | 1600 | |
| Thickness (µm) | 20 | |
| Conductive particles | Type | Au/Ni plating on a polymer core particle with insulation |
| Particle diameter (µmΦ) | 3.5 | |
| Insulation coated particle | Yes | |
| ACF Laminating conditions | Temperature (°C) *4 | 60 to 80 |
| Time (sec) *5 | 2 to 3 | |
| Pressure (MPa) *6 | 0.5 to 1.0 | |
| Main bonding conditions | Temperature (°C) *4 | 160 to 280 |
| Time (sec) *5 | 5 | |
| Pressure (MPa) *7 | 40 to 80 | |
- *1 Minimum space: Space between neighboring circuits.
- *2 Minimum pitch: Total length of conductor width and space between neighboring circuits.
- *3 Minimum connection area: A contact area which needs to trap at least three particles (average -4.5δ) and where the faced conductor overlaps.
- *4 Temperature of ACF lamination and main bonding: It is not equipment temperature, but temperature of ACF.
- *5 Time of ACF lamination and main bonding: Time from the start of bonding to the point where the temperature reaches the target.
- *6 Pressure of ACF lamination: It is described as the area of ACF lamination.
- *7 Pressure of main bonding: The pressure at COG mounting is described as the total area of bumps. The pressure at FOG, FOB, and FOF mounting is described as the bonding area.
Interconnect a small-to-medium-sized LCD with an IC chip.


Note on the characteristic data given - Data on the characteristics of the products described in this page based on the results of evaluations carried out by the company. This does not guarantee that the characteristics of the product conform with your usage environment. Before use, review the usage conditions based on evaluation data obtained from the equipment and substrates actually used.